151-6468 OMR 375 FWhite hydraulic orbital motor 375 cm3 with integrated brake and cylindrical shaft
Price and availability SHIPPING WORLDWIDEThe images are indicative and may differ from the final product delivered.
Availability: Inquire about stock
Price and availabilityPayment and shipping methods
Visa · Mastercard · PayPal · Stripe · Google Pay
DHL · FedEx · UPS
Product identification
- Hidraoil Part number
- GFX101799
- Brand
- White
- Identification number
- 151-6468 OMR 375 F
- Other numbers
- 1516468 OMR375F OMRF
- Approximate weight (kg)
- 14,0
Description
The OMR motor's integrated brake is engaged when no pressure is applied. It releases when at least 21 bar is applied to the brake release port. Brake motors must always have a drain line. Brake release pressure is the difference between the release line pressure and the drain line pressure.
Use the brake only as a static parking brake, never for dynamic braking. Maximum holding torque: 400 Nm. Motors with an integrated brake must always have a connected drain line for correct brake operation.
Shaft type: Straight shaft, 25 mm diameter, with a 8 mm wide parallel key.
Flange: SAE-A type, 2 mounting holes, A2 flange, 82.5 mm centering diameter and 106.4 mm hole spacing.
Gerotor/Geroller width (geroller): 65,0 mm.
Displacement: 372,6 cm3/rev.
Side ports: G1/2 Threaded Ports (1/2" BSPP)
Drain port: G1/4 Threaded Port (1/4" BSPP)
Brake release port: G1/4 Threaded Port (1/4" BSPP)
Maximum brake line pressure: 200 bar.
Maximum speed: 160 rpm (intermittent operation: 200 rpm).
Maximum torque: 300 Nm (intermittent operation: 430 Nm).
Maximum output power: 4,0 kW (intermittent operation: 6,0 kW).
Maximum pressure drop: 55 bar (intermittent operation: 85 bar; peak load:130 bar).
Maximum oil flow: 60 liters/minute (intermittent operation: 75 liters/minute).
Maximum starting pressure with the shaft unloaded: 5 bar.
Minimum starting torque at maximum continuous pressure drop: 240 Nm.
Minimum starting torque at maximum intermittent pressure drop: 380 Nm
Intermittent operation: the stated values are permitted for a maximum of 10% of each minute.
Peak load: the stated values are permitted for a maximum of 1% of each minute.
More information
- Category: Hydraulic Motors
- Category: Orbital
- Category: Sauer Danfoss
- Category: OMR
- Category: With brake - OMR F
- Last updated: 2018-12-04 00:00:01














